Tridor Security will provide a complete installation of fire doors and frames based on our specifications and the materials delivered. We provide experienced installation services catered to your unique requirements. Our tried-and-true installation process provides reliable, accessible, and serviceable installations that are consistent and of a high caliber.

Hinged Fire Doors

A proven fire protection rate of 2.5 hours, manufactured to SANS 1253:2003 (version 3), and rigorously tested by the SABS throughout the years. Compared to conventional fire doors, Tridor fire doors have a number of significant benefits. Both our  single fire doors and our double fire door assemblies have test reports available.

Only 29kg per standard size panel, Tridor fire doors are lightweight and simple to install. They are produced in a variety of sizes and veneer types to complement current surfaces.

A specially built 1,6 mm steel frame with a 25 mm rebate, together with 1.5 pairs of brass hinges, is included with the purchase of  Tridor fire doors. It is possible to construct frames to meet any wall needs, including existing ones.

Door Finishes

Depending on the needs of the customer, doors can be covered in a wide range of finishes, such as Masonite, Sapele Veneer, Commercial Veneer, White Oak Veneer, Walnut Formica, and many others.

All double doors have meeting stiles and slambars installed.

Again, depending on the needs of the customer, a class “D” fire door is completed with either veneer on the exterior side and concealed steel cladding or steel cladding on the exterior side.

Complete the form below to get a quote on Fire Doors.

Which Class

Type of Door

4 + 5 =

Fire Rating

GENERAL REQUIREMENTS

All fire doors are be assembled in the factory and are supplied as complete pre-hung doors. The door may be removed from the frame for ease of erection and to prevent damage during shipping or building activities provided that the frames and doors are number-matched. In accordance with the manufacturer’s instructions, qualified employees may also install locks and closers on-site.

STABILITY

Stability requires that the door or assembly successfully close an opening without the doors slipping out of the frame by greater than 25mm.

INSULATION

The door or assembly must withstand the prescribed fire exposure without the mean exposed face temperature rising above 140°C or the temperature at any exposed face point exceeding 180°C above beginning temperature.

IMPACT TEST

Impact Test (class C & D assemblies only) – The door must be able to withstand two consecutive hits from a sandbag having a diameter of 250 mm and a mass of 27 kg without creating any openings wider than 25 mm. This exam is thoroughly specified in Sections 5.5 and 5.6 of The South African National Standard.

INTEGRITY

Integrity means that the door or assembly must endure the required fire exposure without developing a straight-through gap that is wider than 6 mm at any point.